• Art Photonics, FlexiSpec® Fiber Optic Probes, High Temperature for Harsh Environment
    Art Photonics, FlexiSpec® Fiber Optic Probes, High Temperature for Harsh Environment Art Photonics, FlexiSpec® Fiber Optic Probes, High Temperature for Harsh Environment Art Photonics, FlexiSpec® Fiber Optic Probes, High Temperature for Harsh Environment

FlexiSpec® product line is the latest generation of Attenuated Total Reflection Near & Mid IR-fiber ATR-Probes produced for any type of FT-NIR, FT-IR and other IR-spectrometers, photometers and IR-LED or QCL spectral sensors. ATR immersion fiber optic probes with patented design are suitable for reaction monitoring in lab, pilot plant and for full automated process control.

Fiber Optic ATR-Probes for harsh environment are designed for process-spectroscopy in Near & Mid IR range to monitor reactions in-line in a broad temperature range from -100° to +250°C. They can resist to high pressures up to 200 Bar and used with FTIR or any other IR-spectrometers and spectral sensors in automated process control with process-interfaces.


Key Features

  • High throughput in selected parts of Near & Mid InfraRed-spectra
  • ATR-tip shaped for immersion in liquid flow without dead zone
  • Robust for industrial applications in harsh environment up to 250°C
  • Resistant to high pressure
  • Compatible with all spectrometers and automated process-interfaces

Typical Applications

  • Remote Reaction Monitoring in-line in temperature range -100/+250°C
  • PAT applications in lab, pilot plant or industry with process-interfaces for automated process control
  • Polymerization Process Control
  • In-situ IR-Spectroscopy for PAT in Chemical, Petrochemical, Atomic, Bio-pharmaceutical & Food Industry




Probe TypeDi-ARTSi-ATRZrO2-ATR
Transmission Range

5.2-17 μm

600-1900 cm-1

5.2-17μm

600-3100 cm-1

1.5-6.5μm

600-3100 cm-1

Fiber TypePIR-900/1000 Silver HalidePIR-900/1000 Silver Halide
CIR-500/550 Chalcogenide Glass
Temperature Range-150°C / + 250°C
-150°C / + 250°C
-150°C / + 200°C
Max Pressure200 Bar100 Bar100 Bar


Other Parameters

Total Length1.5 m (1 to 5 m optional)
Shaft Length300 mm (100-500 mm optional)
Shaft Diameter 12 mm
Shaft MaterialHastelloy C22
Length of Legs500 mm (opt. 200 – 500 mm)
Protective Tube MaterialLiquid Tight SS-Conduit, KOPEX-Tube
Minimal Bending Radius130 mm
Input/Output ConnectorsLong SMA (opt.: any other type)
Cooling Air Flow ParametersExcess pressure 0.5 Bar, Flow 2300 L/Hour
Inner Temperature ControlInside shaft to control ART tip temperature



Model Selection



AP10344                             

ATR-P-D-12-30-200/50-HT*

Spectral Range: 5.2-17µm (600-1900cm-1)

Fiber Type: PIR 900/1000

Tip Material: Diamond

200 Bar; -150°C/+250°C

AP10928 (Optional) Tip Protection: crown sized – ATR-P-DC-12-30-200/50-HT
AP10932

ATR-P-Si-12-30-200/50-HT*

Spectral Range: 3.2-17µm (600-3100cm-1)

Fiber Type: PIR 900/1000

Tip Material: Silicon

100 Bar; -150°C/+250°C

AP10512 (Optional)Tip Protection: crown sized – ATR-P-SiC-12-30-200/50-HT
AP10935

ATR-C-ZrO2-12-30-200/50-HT

Spectral Range: 1.1-6.5µm (1550-9000 cm-1)

Fiber Type: CIR 500/550

Tip Material: Cubic Zirconia

100 Bar; -150°C/+200°C

AP10936 (Optional)Tip Protection: crown sized – ATR-C-ZrO2C-12-30-200/50-HT



Thumb File information
Overview-ATR-Probes.pdf 308.53KB
ATR-Probe for Harsh Enviroment.pdf 1.12MB

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha

Art Photonics, FlexiSpec® Fiber Optic Probes, High Temperature for Harsh Environment

  • Brand: Art Photonics
  • Product Code: AP10344
  • Availability: Pre-Order

Related Products

Art Photonics, FlexiSpec® Raman Fiber Probes, Multi-wavelength Excitation (630-785 nm) and Single-wavelength Excitation (532 and 785 nm)

Art Photonics, FlexiSpec® Raman Fiber Probes, Multi-wavelength Excitation (630-785 nm) and Single-wavelength Excitation (532 and 785 nm)

FlexiSpec® product line includes the high sensitivity Raman fiber optic probe to be used with any Ra..

Art Photonics, FlexiSpec® NIRaman Combi Probes, Multi-channel Fiber Optic Probes

Art Photonics, FlexiSpec® NIRaman Combi Probes, Multi-channel Fiber Optic Probes

FlexiSpec® product line includes innovating NIRaman Combi probes.  Raman and NIR spectra contai..

Art Photonics, FlexiSpec® Reflection Fiber Optic Probes,  (7+1) Design

Art Photonics, FlexiSpec® Reflection Fiber Optic Probes, (7+1) Design

Reflection Fiber Optic Probes from FlexiSpec® product line are designed to measure Diffuse and Specu..

Art Photonics, FlexiSpec® Transflexion Dual Pass IR Fiber Optic Probes  for Gases

Art Photonics, FlexiSpec® Transflexion Dual Pass IR Fiber Optic Probes for Gases

FlexiSpec® product line includes the latest generation of Transflexion (dual pass) fiber optic probe..

Art Photonics, FlexiSpec® Sterilizable ART Probes,  Shaft-in-Shaft Design(12.0 mm OD)

Art Photonics, FlexiSpec® Sterilizable ART Probes, Shaft-in-Shaft Design(12.0 mm OD)

Sterilizable ATR Fiber Probe is a new product of FlexiSpec® product line. These ATR Probes are produ..

Art Photonics, Flat Tip ATR Touch Probe, Flat Tip Diamond (600-1900 cm-1) or Germanium (600-3100 cm-1)

Art Photonics, Flat Tip ATR Touch Probe, Flat Tip Diamond (600-1900 cm-1) or Germanium (600-3100 cm-1)

The flat tip ATR crystal design allows touch measurement of sensitive samples and soft solids like s..

Tags: Spectrometer, Microscopy, FTIR, Raman, Sample Preparation, Photonics, Fiber Probe