Per- and polyfluoroalkyl substances (PFAS), including perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS), have emerged as significant environmental contaminants and are now restricted. The EZtrace 6-Channel PFAS Manual SPE System is specifically designed for PFOA/PFOS extraction following EPA methods 533, 537.1, and 1633. This robust, vacuum-controlled extraction workstation combines reliability, ease of use, and high performance, offering a cost-effective alternative to more expensive automated systems.
Low background contamination: This system is designed to minimize the PFAS background. Minimum number of fluid lines with non-Teflon parts makes this system easy to clean after each sample run. Disposable sample reservoirs up to 300mL are used for sample loading and disposed after each use with no need of cleaning. These designs minimize the interference from parts and carryover from sample. The background interference is well below the tightest limits (All values were below 1/3 the regulatory reporting limits for EPA methods).
High efficiency: the 6-channel design allows users to perform up to 6 extractions simultaneously. The unique independent channel design ensures that each extraction is precisely controlled, preventing cross contamination. The high throughput vacuum-control flow saves more time in extraction as compared to automatic SPE system.
Easy to use and low maintenance: This manual vacuum-controlled system has significantly fewer parts in operation requiring minimal cleaning after each run producing much less waste. This robust system is very easy to use, and very little maintenance is required.
Validated for good recovery and high precision: The application for the extraction of PFOS/PFOA compounds is proved using the Empore PFAS 500mg/6mL cartridges by EPA Method 533. The PFAS recovery and repeatability are well within method requirements (see the specs sheet for details). Please feel free to contact us if you need more information or a demo equipment.
Key Features
- Validated for good recovery with high precision for PFAS extraction
- Minimum Teflon parts keep background interference well below the allowance
- Up to 6 channel system perform extraction simultaneously
- Independent channel design to avoid cross-contamination
- High throughput flow path reduces the extraction process time
- Collection of organic and aqueous wastes in separate reservoirs
- Equipped with valve for easy switching between sample collection and waste removal
- Flow can be stopped with valve to allow for solvent soaking steps
- Easy set-up and operation minimizing the training time
- Inert sample pathways prevent corrosion from organic solvents
Typical Applications
- PFOA/PFOS extraction for drinking water and environmental samples
| Product Model | EZ-trace 6-Channel PFAS Manual SPE System |
| Part Number | ASP-SPE-PFAS-M |
| Number of Extraction Channels | 6 |
| PFAS Consumables | Empore PFAS SPE cartridges |
| Dimensions (L×W×H) | 520x290x480 |
| Weight | 14 Kg |
Optional Accessories
| Part Number | Product Description |
| ASP-LV28IICR | Vacuum Pump (Oil-Free), 50mBar, max flow rate 28LPM |
| PFAS-4390-30 | Empore PFAS SPE cartridges. Polymeric WAX sorbent, 500mg/6ml. 30/Pk |
| PFAS-4390-90 | Empore PFAS SPE cartridges. Polymeric WAX sorbent, 500mg/6ml. 90/Pk |
| Thumb | File information |
| CDS Analytical PFAS EZ-tracebrochure.pdf File Size 2.23MB | |
| 230 Empore EZ-Trace Extraction System EPA Method 525.3.pdf File Size 5MB | |
| CDS Empore EZ-Trace Manual-2021.pdf File Size 965.07KB |
CDS Analytical Empore EZ-Trace 6-Channel PFAS Manual SPE System
- Brand: CDS Analytical
- Product Code: SPE-PFAS-M
- Availability: 2-3 Days
Related Products
Advantec Pressure Vessel Stainless Steel 304 Wide-Mouth
This stainless steel pressure vessel is used to propel filtration fluids through pressure holders by..
Advantec Pressure Vessel Stainless Steel 316 Wide-Mouth
This stainless steel pressure vessel is used to propel filtration fluids through pressure holders by..
Vacuum Pump (Oil-Free), Portable and Electric Driven, Maximum Vacuum 25.5 inHg
This portable electric vacuum pump is designed fir demanding applications that require a powerful va..
$811.90
Vacuum Pump ASP-LV28IICR (Oil-Free), Portable and Electric Driven, Anti-Corrosion, Ultimate Vacuum 50mBar, Max Flow Rate 28LPM
The laboratory diaphragm vacuum pump is equipped with automatic cooling exhaust system to ensure con..
$767.05
Biocomma Solid Phase Extraction (SPE) Vacuum Manifolds, 12 Ports
The SPE vacuum manifolds are designed to process 12 or 24 samples in parallel. As a tool used ..
$640.98
Scientific Universal Vacuum Manifold, Adapted to 48/96/384-well Plates
The Universal Vacuum Manifolds are specially designed for high-throughput nucleic acid purification,..
$798.00
Biocomma Adjustable Oil-Free Vacuum Pump, Pressure: 0.02~0.08MPa, Max. Flow Rate 30L/min
The Universal Vacuum Manifolds are specially designed for high-throughput nucleic acid purification,..
$360.80
Adapters & Connectors: Short Flangeless PEEK Fittings, Headless, 1/4''-28 Nuts, Ferrules and Locking Ring (100 Pcs/Pk)
PEEK (polyetheretherketone) is a semi-crystalline thermoplastic known for its exceptional chemical r..
$680.00
Solid Phase Extraction (SPE) Cartridges for PFAS
A group of SPE cartridges with proven efficiency in PFAS extraction using EPA method 533 and 537.1 a..
$450.00
GL Sciences Delay Column for PFAS
Delay Column for PFAS is packed with high-purity activated carbon, which is able to retain contamina..
$660.00
HPLC Column, InertSustain C18 and AQ-C18, Pore Size 3um for PFAS Analysis
PFAS analysis in EPA method 533 uses analytical column C18, 2x50mm, 3um or equivalent. EPA met..
$840.00
HPLC Column, Welch Ultisil AQ-C18 and XB-C18, Particle Size 3μm for PFAS Analysis
PFAS analysis in EPA method 533 uses analytical column C18, 2x50mm, 3um or equivalent. EPA met..
$450.00
Tags: PFAS, Consumable, Empty SPE Cartridges, SPE, Vacuum Pump