• Micro Spectrometer, Cooled, Ultra High Resolution Optical Fiber Spectrometer ATP5030/5034
ATP5030/4 is a cooled, ultra-high-resolution micro spectrometer, which is based on the M-type optical path structure.  It uses a cooled 2048- or 4096-pixel linear array detector to achieve the ultra-high resolution (up to 0.05nm).  It features high reliability, ultra-high-speed and cost-effectiveness and is widely used in environment applications, such as online testing.   ATP5030 can receive SMA905 optical fiber input light or free space light and output the measured spectrum data through USB2.0 or UART port. It only requires a 5VDC power supply, making it easy to be integrated. 

Key Features

  • Detector cooling temperature: -5C
  • M type optical path, higher resolution
  • Spectral range: 200-1100 nm
  • Spectral resolution: 0.05-2 nm
  • Optical path structure: non-crossing C-T
  • Detector: 2048 or 4096 pixels
  • Integration time: 0.1ms -256s
  • Power supply: 5VDC power supply
  • ADC bit depth: 16 bits
  • Data output interface: USB Type-C
  • 20-pin expansion interface.

Typical Applications 

  • LIBS, Plasma luminescence detection
  • Raman spectroscopy detection
  • Wavelength monitoring, laser, LED and other luminous bodies.
  • Water quality analyzer
  • UV flue gas analyzer
  • LED sorting machine, color detection
  • Spectral analysis, radiation spectroscopic analysis, spectrophotometric analysis
  • Reflection and transmission spectrum detection.


Detector pixel
ATP50302048

ATP50344096
ATP5030P2048Cooled, Back-thinned CCD
Detector
Type
Linear array detector
Detectable range
200-1100 nm
Effective pixel
2048 or 4096 pixels
Sensor Cooled
TEC cooled, -5 ˚C
Pixel dimension
14μm × 200μm
Sensitivity1300 V/(lx·s)
Dark noise
13 RMS @ 13 ˚C
Optical Parameter

Wavelength range
200-1100 nm
Optical resolution
0.07-3 nm
Signal-to-noise
>600:1
Dynamic range8.5 x 107 (system); 2000:1 for a single acquisition
Stray light
<0.05% at 600 nm; <0.09% at 435 nm
Optical Configuration

Optical DesignCzerny-Turner
Focal Distance
75mm
Incidence slit
50μm (10, 25, 100, 200μm are optional)
Incident InterfaceSMA905 connector
Data interface
SMA905 connector
Electrical Parameter

Integration time
0.1ms - 256 second
Interfaces

USB Type-C

A/D conversion resolution
16 bits
Supply voltage
DC4.5 to 5.5 V (type @5V)
Operating current
1.5 A @Typical. 3A Max
Storage temperature
-30°C to +70°C
Operating temperature
-25 ~ 50C
Physics Parameter

Dimension
135 × 99 × 46 mm
Weight
0.5 kg
SealingAnti-sweat
Thumb File information
Aurora-ATP5030high resolution Optical fiber spectrometer .pdf 244.97KB

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha

Micro Spectrometer, Cooled, Ultra High Resolution Optical Fiber Spectrometer ATP5030/5034


Related Products

Spectral Libraries Raman

Spectral Libraries Raman

New Raman spectra are continuously added to this database making it the largest and most advanced Ra..

Portable Raman Analyzer, 532nm, 633nm, 785nm, 1064nm Excitation Wavelengths

Portable Raman Analyzer, 532nm, 633nm, 785nm, 1064nm Excitation Wavelengths

ASP-ATR8000 portable Raman Analyzer is an all-auto detection instrument for improving detection thro..

Micro Spectrometer, High Resolution NIR ATP8730

Micro Spectrometer, High Resolution NIR ATP8730

ATP8730 is an ultra-high-resolution, high-speed, short-wave infrared series micro-optic spectromet..

Micro Spectrometer, Ultra-Thin  Optic ATP2400

Micro Spectrometer, Ultra-Thin Optic ATP2400

ATP2400, a high-performance ultra-thin fiber spectrometer features built-in pulsed xenon lamp drive ..

Micro Spectrometer, High Performance Fiber Optical NIR Spectrometer ATP8600

Micro Spectrometer, High Performance Fiber Optical NIR Spectrometer ATP8600

The mini fiber optic spectrometer ATP8600 features InGaAs linear detector of 256 pixels, compact des..

Tags: Spectrometer, Spectroscopy