In-situPro IR is a high-sensitive in-situ mid-FTIR spectrometer developed for field application, reaction monitoring and chemical process control in both academia and industry. It is a plug-and-play instrument including an IR source, high-stability interferometer, ultra-sensitive IR detector, and versatile sampling accessories for different applications. The small footprint size saves valuable space and offers flexibility to deploy In-situPro IR in various locations across the lab and industrial plants. Its low power rating (12V, 30W) also allows its use in field applications.
It is equipped with thermo-electrically (TE) cooled MCT detectors to deliver high performance without the need for liquid nitrogen. The TE-cooled detectors in the FTIR-FC are the most sensitive TE-cooled detectors available on the market and offer a reliable and maintenance-free operation. For ultimate sensitivity levels, the In-situPro IR can also be equipped with a liquid-nitrogen cooled detector. The TE and liquid-nitrogen cooled detectors are interchangeable by the user.
In-situPro IR uses a modular software platform SpectraCode for spectroscopic data processing, visualization, and reporting. It also has a reaction monitoring add-on to record a series of spectra, analyze and monitor the trends of peaks, or predicted properties derived from all recorded spectra. Trends are displayed as graph and tabulated values with additional statistical information, such as the best polynomial fit function and regression coefficient. Spectra and the region of interest are shown either as a 2D spectral overlay, or a 3D plot.
The In-situPro IR spectrometer can be coupled with different sampling accessories for different applications. Please feel free to contact us to discuss your applications or request a demo.
- Transmission accessories for solid and liquid sample testing in lab or field.
- Transmission flow cell for liquid transmission spectroscopy on a high pressure, high temperature, low volume of liquid. A peristaltic pump can be used to deliver the sample into the flow cell continuously for reaction monitoring or processing.
- Fibered reflection probes to measure specular or diffuse reflection in FT-IR systems. They are especially well suited for applications requiring a lot of flexibility. We offer fibered probes of three different kinds, depending on the fiber constituting glass, each targeting a specific spectral range. Light is brought to the sample via a peripheral fiber bundle which helps in achieving homogeneous illumination, and is collected by single, central fiber. A list of the three types of reflection probes can be found under the Specification tab.
- ATR fiber probes for chemical process monitoring. These probes can be immersed into highly corrosive liquids at high temperatures and pressures, making them suitable for use in chemical reaction vessels and other extremely harsh environments. A list of available probes can be found under the Specification tab.
Key Features
- All-in-one solution including light source, interferometer, detector and sample accessories.
- TE cooled MCT detector, no liquid nitrogen needed
- Flexible, portable, and most compact FTIR spectrometer on the market
- Flexible and robust for lab and industrial applications in harsh environment
- Reaction monitoring software included
- Small footprint (18cm x 16cm x 8cm)
Typical Applications
- Field sample testing
- Reaction Monitoring in real time
- Process Analytical Technologies (PAT)
- Remote Polymerization Control
- Crystallization Process Screening In-situ IR-Spectroscopy for PAT in Chemical, Petrochemical, Atomic, Biopharmaceutical & Food Industry
Specification of FTIR Spectrometer
| Product Model | In-situPro IR-4TE | In-situPro IR-LN |
| Spectra Range (1/cm) | 5000 -800 | 5000 -625 |
| Spectra Range (um) | 2-12 | 2-16 |
| Detector Type | MCT, 4-TE cooled | MCT, liquid nitrogen cooled |
| Detector D | >2.5E9 (cm Hz^1/2W^-1) | >3E10 (cm Hz^1/2W^-1) |
| Interferometer Type | Permanently aligned, double retro-reflector design | Permanently aligned, double retro-reflector design |
| Beam-splitter material | ZnSe | ZnSe |
| Resolution (unapodized) | 8, 4 [cm-1] | 8,4 [cm-1] |
| Wavenumber repeatability | <10PPM | <10PPM |
| Scan frequency | 1 spectrum / second | 1 spectrum / second |
| Reference laser | Temperature-stabilized solid-state laser @850nm | Temperature-stabilized solid-state laser @850nm |
| Integrated light source | 20W SiC globar with electronic stabilization | 20W SiC globar with electronic stabilization |
| Operating temperature | 5°C-40°C | 5°C-40°C |
| Fiber optic interfaces | SMA 905 connectors, fiber core up to Ø 1mm, NA=0.3 | SMA 905 connectors, fiber core up to Ø 1mm, NA=0.3 |
| Power Requirement | 12V/30W | 12V/30W |
| Connector | 2 connectors for 4mm OD tubes | 2 connectors for 4mm OD tubes |
| Communication Interface | USB2.0 | USB2.0 |
| Software Interface | Win7/10 API controlling the instrument via DLL | Win7/10 API controlling the instrument via DLL |
| Software | Spectacode | Spectacode |
| Over Dimensions (mm) | 180 x 160 x 80 | 180 x 160 x 80 |
| Weight | 2.2 Kg | 2.2 Kg |
Specification of IR Reflection Probes
| Product Model | R7-NIR-600-200F | R7-CIR-500-150F | R7-PIR-900-150F |
| Spectra Range (um) | 0.4-2.5 | 2- 5.5 | 4-16 |
| Illuminating fiber bundles | 6x low-OH, 600 µm core silica fibers | 6x 500 µm core diameter CIR fibers | 7x 400 µm core diameter PIR fibers |
| Reading fiber | low-OH, 600 µm core silica fibers | 500 µm core diameter CIR fibers | 900 µm core diameter PIR fibers |
| Probe Ferrule | SS ferrule ø¼’’(3.18mm x 74mm) | SS ferrule ø¼’’(6.35mm x 74mm) | SS ferrule ø¼’’(6.35mm x 74mm) |
| Length(m) | 2 | 1.5 | 1.5 |
| Fiber Connector | SMA905 | SMA905 | SMA905 |
| Recommended Instrument | FTNIR-FC-025-2TE | FTMIR-FC-060-2TE | FTMIR-FC-120-4TE |
Specification of Fiber Optic Standard ATR-Probes
| Probe Type | Di-ATR | ZnSe-ATR | Si-ATR | ZrO2-ATR |
| Transmission Range | 5.2-16.7 μm | 3.2-16.7μm | 3.2-16.7μm | 1.1-6.7μm |
| Fiber Type | PIR-900/1000 Silver Halide | PIR-900/1000 Silver Halide | PIR-900/1000 Silver Halide | CIR 500/550 Chalcogenide glass |
| Temperature Range | -100°C / + 140°C | -100°C / + 140°C | -100°C / + 140°C | -100°C / + 90°C |
| Pressure (max) | 200 -300 Bar | 10 Bar | 100 Bar | 100 Bar |
Related Products
FT-NIR Rocket, Fibered NIR Spectrometer, Spectral Range from 900 to 2600nm
The FT-NIR Rocket is a high-performance system combining high resolution, broad wavelength range and..
ARCoptix Fiber Coupler FTMIR-FC-060-4TE 2.0-6.0μm
The ARCoptix FT-IR spectrometer is an all-fibered alternative to our "Rocket" configurations. It fea..
ARCoptix Fiber Coupler FTMIR-FC-160-LN2 2.0-16.0μm
The ARCoptix FT-IR spectrometer is an all-fibered alternative to our "Rocket" configurations. It fea..
FTIR Fiber Coupler and Collimator
Lens-based coupler provides a cost-effective solution for fiber coupling& collimation. Bk7 coupl..
Tags: Spectrometer, Spectroscopy, Analytical Instrument, FTIR